Shop - Bunker Builders https://www.bunkerbuilders.com/shop/ Everything You Need to Know About Building & Surviving in a Bunker Fri, 30 Jan 2026 15:54:36 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.1 https://i0.wp.com/www.bunkerbuilders.com/wp-content/uploads/2025/10/logo-coming-soon-300x300-1.png?fit=32%2C32&ssl=1 Shop - Bunker Builders https://www.bunkerbuilders.com/shop/ 32 32 252268266 Fortress Series High Security Doors https://www.bunkerbuilders.com/product/fortress-series-high-security-doors/?utm_source=rss&utm_medium=rss&utm_campaign=fortress-series-high-security-doors https://www.bunkerbuilders.com/product/fortress-series-high-security-doors/#respond Fri, 30 Jan 2026 15:41:25 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=892 Forced Entry Resistant Doors For Home & Business Download Fortress Technical and Installation Specifications > The Shield Fortress Series is designed to help create a secure environment for locations with extremely high threat profiles or security challenges. It has been tested at NTS Chesapeake in Belcamp, MD and at Intertek in York, PA to the […]

The post Fortress Series High Security Doors appeared first on Bunker Builders.

]]>
Forced Entry Resistant Doors For Home & Business

Download Fortress Technical and Installation Specifications >

The Shield Fortress Series is designed to help create a secure environment for locations with extremely high threat profiles or security challenges. It has been tested at NTS Chesapeake in Belcamp, MD and at Intertek in York, PA to the US State Department (DoS) forced entry standard SD-STD.01.01 Rev. G at the 15 minute level (FE15), ASTM F3038 15 minute, the UL752 ballistic standard (level 3 and 8), and the National Institute of Justice (NIJ) ballistic standard 0101.06 levels III and IIIA. It has also been tested and certified at the iFT Rosenheim laboratory in Germany at the resistance class 4 (RC4) rating according to EN1627.

Our highly specialized manufacturing process makes us the best choice for door restoration and reproduction projects. We design our doors for both interior and exterior applications in residential and commercial properties. We can easily match the design of other doors on your property to ensure that the only person who knows about your security door or window is…you.

You don’t compromise on style; we never compromise on security. It’s military-grade security at your door.

About the Shield Fortress Series High-Security Door

Our top-of-the-line forced entry-resistant door is custom designed for locations at very high risk of burglary or forced entry (bullet-resistant upgrade options available).

 Special Features

Fortress Series FE15

One of our core beliefs is that the secret to good security is to keep it a secret. That’s because security is much harder to defeat when you can’t see it and don’t know what you’re up against. Our custom made high-security doors and windows can be designed to look like just about anything, including unique wood stains, 3D millings, and custom shaped glass.

The Essential Details of the Fortress Series Forced Entry Resistant Door
  1. Armored multi-point locking system encased in drill-resistant manganese.
  2. Optional motorized lock with a biometric fingerprint scanner, keypad, card reader, or integration with a 3rd party access control system.
  3. High-security Mul-T-Lock keys and cylinders.
  4. Adjustable security hinges that make even the heaviest doors easy and comfortable to operate.
  5. 3-½” thick door and 4-½” wide frame.
  6. 2” thick layer of rockwool and double gasketing for outstanding sound and heat insulation.
  7. A virtually unlimited range of architectural designs, natural hardwood or engineered wood door skins, raised panels, millings, glazings, and colors that allow us to create highly secure and beautiful doors.

mtl-mt5Mul-T-Lock Cylinders

Mul-T-Lock’s MT5+ cylinders are a natural fit in our doors. Mul-T-Lock keys cannot be copied and even the installer’s green key is automatically deactivated when the homeowner starts using the yellow key. A master red key deactivates all others if any yellow keys are lost or stolen, providing the ultimate in security and key control.

 

 


flamFIAM X1R Electromechanical Lock

The Fiam X1R electromechanical locking system is the most sophisticated and secure electronic lock on the market. Locking in three directions with up to 20 bolts, the X1R can be integrated with keypads, biometrics, card readers, or any other access control system. Never again will you ask yourself “did I lock the door?” because the X1R ensures that your door is always secured.

 

 


Mottura 85/87 Series Mechanical Lock

The Mottura 85 and 87 series armored mechanical multi-point locks are the most robust and durable mechanical locking solutions in the world. They secure the door in three directions with up to 20 bolts and have a unique patented design that protects the key cylinder from attack.

 

 

 

 


 

ekey Biometric scanner

Fingerprint scanners offer the ultimate in biometric security. They are convenient, affordable, safe, and reliable. The scanner analyses each fingerprint swipe to provide a unique thermal signature and a special code to open the door. Up to 99 different fingerprints can be stored, and adding or removing authorised fingerprints is easy.


Door Layouts

fortress-web-door-layout

KEY DETAIL OPTIONS
  • Transom: non-operable window above a door
  • Sidelite: non-operable window beside a door
  • Arched door: door curved at the top
  • Arched transom: curved window above a door

Test & Certifications

How We Test Our Doors

  • 4.5 man-hours of attack time
  • Six man team spends 15 minutes attacking the center of the door, 15 minutes on the lock side, 15 minutes on the hinge side
  • Expanded list of tools used including sledgehammers, crowbars, axes, battering ram, wedges, propane torch, bolt cutters, and hacksaw
  • UL752 level 3 and level 8 bullet resistant (optional)

Additional Testing Details

The Shield Fortress Series was tested at NTS Chesapeake in Belcamp, MD, and Intertek in York, PA, to the US State Department (DoS) forced entry standard and ASTM F3038-14 at the 15-minute level (FE 15) and at the Kaunas University of Technology, achieving a resistance class 4 (RC 4) rating under EN1627. This certifies that the Shield Fortress Series can withstand entry from highly skilled attackers using heavy-duty tools such as crowbars, sledgehammers, axes, wedges, saws, steel-cutting pliers, and power drills. The Fortress Series was also tested for bullet resistance to UL752 levels 3 and 8, NIJ levels III and IIIA, and European standard EN1522 levels FB4 and FB6. The door is suitable for government offices, commercial buildings, private homes, and apartments.

Door Ratings Matter
What level of protection does the Shield Fortress Series offer?

  • FE15 rating under SD-STD.01.01 Rev. G (US State Department)
  • FE15 rating under ASTM F3038-14 (American Society for Testing and Materials)
  • RC4 (Resistance Class 4) rating under European Standard EN 1627
  • UL level 3 or 8 bullet-resistant (optional)
  • NIJ level III or IIIA bullet-resistant (optional)

The post Fortress Series High Security Doors appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/fortress-series-high-security-doors/feed/ 0 892
Expansion Chambers RK https://www.bunkerbuilders.com/product/expansion-chambers-rk/?utm_source=rss&utm_medium=rss&utm_campaign=expansion-chambers-rk https://www.bunkerbuilders.com/product/expansion-chambers-rk/#respond Mon, 15 Dec 2025 06:23:24 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=850 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post Expansion Chambers RK appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

Expansion Chambers RK

Expansion chambers RK type are used to reduce the blast wave pressure after the blast dampers. Our range includes three types of metal expansion chambers: RK-0.5 (volume 0.5 m3); RK-2-I (volume 2 m3, air inlet from the side) RK-2-II (volume 2 m3, air inlet from the top). On request, it is possible to manufacture the RCF-6 product with built-in prefilters.
Other spaces can be used as expansion chambers – reinforced concrete rooms, sections of the air duct, and other.

The post Expansion Chambers RK appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/expansion-chambers-rk/feed/ 0 850
Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers https://www.bunkerbuilders.com/product/special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers/?utm_source=rss&utm_medium=rss&utm_campaign=special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers https://www.bunkerbuilders.com/product/special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers/#respond Mon, 15 Dec 2025 06:20:51 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=847 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers

MZ-2 and UZ-3 cases can be used for placing the MZS and UZS-1 blast dampers on vertical / horizontal air ducts (side opening).

The post Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers/feed/ 0 847
UZS-8 Blast Damper Combined with an Emergency Hatch https://www.bunkerbuilders.com/product/uzs-8-blast-damper-combined-with-an-emergency-hatch/?utm_source=rss&utm_medium=rss&utm_campaign=uzs-8-blast-damper-combined-with-an-emergency-hatch https://www.bunkerbuilders.com/product/uzs-8-blast-damper-combined-with-an-emergency-hatch/#respond Mon, 15 Dec 2025 06:18:47 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=844 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post UZS-8 Blast Damper Combined with an Emergency Hatch appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

UZS-8 Blast Damper Combined with an Emergency Hatch

UZS-8 is an assembly that includes UZS-1 blast damper installed in the special metal casing and can be used as an emergency hatch.

The post UZS-8 Blast Damper Combined with an Emergency Hatch appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/uzs-8-blast-damper-combined-with-an-emergency-hatch/feed/ 0 844
MZS Assembly https://www.bunkerbuilders.com/product/mzs-assembly/?utm_source=rss&utm_medium=rss&utm_campaign=mzs-assembly https://www.bunkerbuilders.com/product/mzs-assembly/#respond Mon, 15 Dec 2025 06:15:47 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=841 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post MZS Assembly appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

MZS Assembly

MZS assembly includes MZS blast damper installed in the special metal casing that includes flange with opening of 200 mm diameter. 
The steel casing protects the MZS blast damper from mechanical and weather damages with option to install electric heating wire preventing freezing.

The post MZS Assembly appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/mzs-assembly/feed/ 0 841
UZS – Blast Damper https://www.bunkerbuilders.com/product/uzs-blast-damper/?utm_source=rss&utm_medium=rss&utm_campaign=uzs-blast-damper https://www.bunkerbuilders.com/product/uzs-blast-damper/#respond Mon, 15 Dec 2025 06:12:52 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=838 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post UZS – Blast Damper appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

UZS – Blast Damper

  • ​UZS Protective section designed to protect ventilation devices of special-purpose buildings from the effects of a shock wave of long duration with a pressure up to 10 kg/cm² (1000 kPa)

  • Protective sections closes automatically, under the pressure of the blast wave, covering ventilation openings or air ducts and provide protection against the penetration of a blast wave into the shelter.

  • Min Size: 595 mm x 649 mm (W x H)

  • Weight: 25 kg

  • Airflow: 8000 m3/h

  • Pressure drop: up to 210 Pa

  • Blast wave pressure resistance: long duration 0.3 to 10 kg/cm² (30-1000 kPa)

The post UZS – Blast Damper appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/uzs-blast-damper/feed/ 0 838
MZS – Blast Damper https://www.bunkerbuilders.com/product/mzs-blast-damper/?utm_source=rss&utm_medium=rss&utm_campaign=mzs-blast-damper https://www.bunkerbuilders.com/product/mzs-blast-damper/#respond Mon, 15 Dec 2025 06:09:07 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=835 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post MZS – Blast Damper appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

MZS – Blast Damper

​MZS protective section designed to protect ventilation devices of special-purpose buildings from the effects of a shock wave of long duration with a pressure up to 10 kg/cm² (1000 kPa)

Protective sections closes automatically, under the pressure of the blast wave, covering ventilation openings or air ducts and provide protection against the penetration of a blast wave into the shelter.

  • Min Size: 282 mm x 321 mm (W x H)

  • Weight: 5 kg

  • Airflow: 1500 m3/h

  • Pressure drop:  up to 250 Pa

  • Blast wave pressure resistance: long duration 0.3 to 10 kg/cm² (30-1000 kPa)

Download Brochure >

The post MZS – Blast Damper appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/mzs-blast-damper/feed/ 0 835
HDB – Blast Damper https://www.bunkerbuilders.com/product/hdb-blast-damper/?utm_source=rss&utm_medium=rss&utm_campaign=hdb-blast-damper https://www.bunkerbuilders.com/product/hdb-blast-damper/#respond Mon, 15 Dec 2025 06:08:47 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=832 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post HDB – Blast Damper appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

HDB – Blast Damper

  • MIN Size: 200 mm x 200 mm (W x H)

  • MAX Size: 2000 mm x 2400 mm (W x H),

  • Shock tube tested (Maximum pressure is 6 bar, 12.9ms; 1.1 bar, 57ms (peak reflected pressure), VTT

  • ATEX certified (Gas) IIC, Zone 1 & 2, IIC, T6…T2 (Dust), Zone 21 & 22, IIIB, T70ºC~T285ºC, TUV

  • The normal operating temperature is between -40 ºC to +300 ºC, 30 mins, SGS

  • Aerodynamic testing according to AMCA-500

  • Excellent corrosion resistance, passed the 1440h salt spray corrosion test follow the standard DIN EN ISO 9227: 2006

  • Equipped with grid preserving from the debris impact

  • Self-actuating closing and opening

Download Brochure >

The post HDB – Blast Damper appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/hdb-blast-damper/feed/ 0 832
GK 100-800 – Gastight Valve with Motorized Operation https://www.bunkerbuilders.com/product/gk-100-800-gastight-valve-with-motorized-operation/?utm_source=rss&utm_medium=rss&utm_campaign=gk-100-800-gastight-valve-with-motorized-operation https://www.bunkerbuilders.com/product/gk-100-800-gastight-valve-with-motorized-operation/#respond Fri, 12 Dec 2025 12:38:46 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=829 GK gastight valves are flow regulation valves designed for installation on the air ducts of ventilation systems of shelters and protective structures. The valves are commonly used as shut-off devices to stop or control the airflow and protect the inner space.

The post GK 100-800 – Gastight Valve with Motorized Operation appeared first on Bunker Builders.

]]>

GK gastight valves are flow regulation valves designed for installation on the air ducts of ventilation systems of shelters and protective structures. The valves are commonly used as shut-off devices to stop or control the airflow and protect the inner space.

Advantages

  • GK gastight shut-off valves have special design with double eccentric axle.

  • GK valves can be delivered with manual and motorized drive.

  • The valves are designed to hold a high static pressure loads and can be used in ventilation systems of shelters and protected facilities.

  • The valves have a welded steel body or optionally can be made from stainless steel for very corrosive environments.

  • The valve can be installed at any direction on the air duct.

  • Minimal effort to operate the valve;

  • When opening / closing, there is no friction of the sealing ring on the seat;

  • Long service life of the sealing elements;

  • Replacing the seal is a simple procedure that does not require special tools;

  • Continuous sealing surface (360 degrees) provides the highest class of tightness.

GK 100-800 – Gastight Valve with Motorized Operation (Motor + Gear)

  • Nominal opening diameter: 100-800 mm

The post GK 100-800 – Gastight Valve with Motorized Operation appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/gk-100-800-gastight-valve-with-motorized-operation/feed/ 0 829
GK 400-800 – Gastight Valve with Manual Operation https://www.bunkerbuilders.com/product/gk-400-800-gastight-valve-with-manual-operation/?utm_source=rss&utm_medium=rss&utm_campaign=gk-400-800-gastight-valve-with-manual-operation https://www.bunkerbuilders.com/product/gk-400-800-gastight-valve-with-manual-operation/#respond Fri, 12 Dec 2025 12:36:26 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=826 GK gastight valves are flow regulation valves designed for installation on the air ducts of ventilation systems of shelters and protective structures. The valves are commonly used as shut-off devices to stop or control the airflow and protect the inner space.

The post GK 400-800 – Gastight Valve with Manual Operation appeared first on Bunker Builders.

]]>

GK gastight valves are flow regulation valves designed for installation on the air ducts of ventilation systems of shelters and protective structures. The valves are commonly used as shut-off devices to stop or control the airflow and protect the inner space.

Advantages

  • GK gastight shut-off valves have special design with double eccentric axle.

  • GK valves can be delivered with manual and motorized drive.

  • The valves are designed to hold a high static pressure loads and can be used in ventilation systems of shelters and protected facilities.

  • The valves have a welded steel body or optionally can be made from stainless steel for very corrosive environments.

  • The valve can be installed at any direction on the air duct.

  • Minimal effort to operate the valve;

  • When opening / closing, there is no friction of the sealing ring on the seat;

  • Long service life of the sealing elements;

  • Replacing the seal is a simple procedure that does not require special tools;

  • Continuous sealing surface (360 degrees) provides the highest class of tightness.

GK 400-800 – Gastight Valve with Manual Operation (gear)

  • Nominal opening diameter: 400-800 mm

The post GK 400-800 – Gastight Valve with Manual Operation appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/gk-400-800-gastight-valve-with-manual-operation/feed/ 0 826