MZS Archives - Bunker Builders https://www.bunkerbuilders.com/product-tag/mzs/ Mon, 15 Dec 2025 06:23:00 +0000 en-US hourly 1 https://wordpress.org/?v=6.9 https://www.bunkerbuilders.com/wp-content/uploads/2025/10/logo-coming-soon-300x300-1-150x150.png MZS Archives - Bunker Builders https://www.bunkerbuilders.com/product-tag/mzs/ 32 32 Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers https://www.bunkerbuilders.com/product/special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers/?utm_source=rss&utm_medium=rss&utm_campaign=special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers https://www.bunkerbuilders.com/product/special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers/#respond Mon, 15 Dec 2025 06:20:51 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=847 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers

MZ-2 and UZ-3 cases can be used for placing the MZS and UZS-1 blast dampers on vertical / horizontal air ducts (side opening).

The post Special Cases MZ-2 and UZ-3 for MZS and UZS-1 Blast Dampers appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/special-cases-mz-2-and-uz-3-for-mzs-and-uzs-1-blast-dampers/feed/ 0 847
MZS Assembly https://www.bunkerbuilders.com/product/mzs-assembly/?utm_source=rss&utm_medium=rss&utm_campaign=mzs-assembly https://www.bunkerbuilders.com/product/mzs-assembly/#respond Mon, 15 Dec 2025 06:15:47 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=841 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post MZS Assembly appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

MZS Assembly

MZS assembly includes MZS blast damper installed in the special metal casing that includes flange with opening of 200 mm diameter. 
The steel casing protects the MZS blast damper from mechanical and weather damages with option to install electric heating wire preventing freezing.

The post MZS Assembly appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/mzs-assembly/feed/ 0 841
MZS – Blast Damper https://www.bunkerbuilders.com/product/mzs-blast-damper/?utm_source=rss&utm_medium=rss&utm_campaign=mzs-blast-damper https://www.bunkerbuilders.com/product/mzs-blast-damper/#respond Mon, 15 Dec 2025 06:09:07 +0000 https://ffb.ios.mybluehost.me/website_81fe6ff5/?post_type=product&p=835 Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

The post MZS – Blast Damper appeared first on Bunker Builders.

]]>

Blast dampers are used in ventilation systems to prevent the blast wave through external walls into the building. They are designed with high ventilation capacity. The dampers can protect people and equipment from explosions or momentary pressure change (e.g. tornadoes, etc.). When an explosion occurs, the valve will close instantly under the action of the shock wave; when the shock wave disappears, the valve will be automatically restored. They are mainly used in refineries, oil & gas, nuclear power plants and some other facilities which are at risk of explosions. They are installed on the air openings (air inlet and air outlet) of the facilities.

MZS – Blast Damper

​MZS protective section designed to protect ventilation devices of special-purpose buildings from the effects of a shock wave of long duration with a pressure up to 10 kg/cm² (1000 kPa)

Protective sections closes automatically, under the pressure of the blast wave, covering ventilation openings or air ducts and provide protection against the penetration of a blast wave into the shelter.

  • Min Size: 282 mm x 321 mm (W x H)

  • Weight: 5 kg

  • Airflow: 1500 m3/h

  • Pressure drop:  up to 250 Pa

  • Blast wave pressure resistance: long duration 0.3 to 10 kg/cm² (30-1000 kPa)

Download Brochure >

The post MZS – Blast Damper appeared first on Bunker Builders.

]]>
https://www.bunkerbuilders.com/product/mzs-blast-damper/feed/ 0 835